16 May, 01:00 · Diesel · 143.4 kg

Grid · off since 01:00

Every hour of compute,accounted for.

This is your facility, seen by a thermal camera. Snowleaf measures every hour of that heat — grid, generator and solar — and shows its working.

1.0 — What the meter shows

Generators cost the most.Snowleaf finds every hour.

One year of readings from Baobab Site A, our sample facility, read hour by hour. Three things a monthly energy bill never tells you.

  • 444

    hours on generators

    5.1% of the year, nine in ten of them before August. The year below shows exactly which hours.

  • 7.7%

    of the emissions came from those hours

    58.41 of 758.66 tonnes CO₂e. One in twenty hours, one in thirteen tonnes.

  • 1.46

    power usage effectiveness

    For every kWh the servers used, the site spent 0.46 more on cooling and power. 68% of the energy reached the servers.

2.0 — The year, hour by hour

8,760 hours.Each one on the record.

tCO₂e for the year
758.66
hours on diesel, before and after August
7.8% → 1.3%

70kgCO₂e per hour155

Baobab Site A (sample) · real engine run · 2026

3.0 — Today, and with Snowleaf

Most energy figures are estimates.Yours don’t have to be.

How energy figures are produced today, and with Snowleaf
TodayWith Snowleaf
Where the numbers come fromToday: Monthly bills, typed into a spreadsheetWith Snowleaf: Every meter — grid, generator, solar — hour by hour
Generator useToday: Worked out afterwards from fuel receiptsWith Snowleaf: Every hour the generators ran, and what it emitted
Emission factorsToday: Copied from wherever was to handWith Snowleaf: Every factor shown with its source and year
“Where is this number from?”Today: Days of digging through old filesWith Snowleaf: One click back to the reading and the file it came in
A finished reportToday: Edited in place; nobody knows what changedWith Snowleaf: Versioned and fingerprinted, so any change shows

4.0 — Measure

Upload a file.Every row is checked.

Grid, generator and solar readings by the hour, straight from your meters or a spreadsheet. Good rows load. Bad rows are listed with the reason — never quietly fixed.

baobab-site-a-readings.csv

  1. 02:00Diesel generator55.8 litres
  2. 03:00Diesel generatorNot loaded — quantity: missing or not a number—
  3. 06:00Grid214.6 kWh
  4. 06:00Facility total (meter)196.6 kWh
  5. 07:00Grid208.9 kWh
  6. 08:00GridNot loaded — unit: expected kWh, got litres—
  7. 12:00Rooftop solar71.3 kWh

5 loaded2 rejected

Real response from Snowleaf’s ingest

Snowleaf

Emissions report · v1 draft

Baobab Site A, 2026

1 Jan – 31 Dec 2026 · method 0.1.0 · completeness 100% · PUE 1.46

758.66tCO₂e

Emissions by source
SourceScopetCO₂eShare
Grid electricity2700.2592.3%
Diesel generators158.417.7%
Rooftop solar—0.000.0%

Status

Draft · self-reported, method documented

Self-reported · method documented

5.0 — Report

A report your signercan put their name to.

Totals by source and scope, and the factor behind every figure with its source and year. Each version carries a fingerprint of its contents, so anyone can tell if it has changed.

6.0 — Trust

One total, walked backto a file you can check.

Nobody should have to take a total on trust. Here is one real chain from this sample — click through it.

Don’t take our word for it.

Download the sample file and your browser computes its SHA-256 itself.

7.0 — See it for yourself

Read a full report.Then send it to finance.

The complete Baobab Site A report for 2026: totals by source and scope, every factor with its source, and the trail from each total back to its file. Made from sample data, and labelled that way on every page.

Who it’s for

Three people need these numbers.Each needs them for a different reason.

  • Operators

    Colocation and data-centre operators whose tenants are asking for figures they can rely on.

    Gets: hourly emissions per facility, PUE for the period, a report to hand tenants.

  • Reporters

    Banks, telcos and multinationals running their own server rooms.

    Gets: Scope 1 and 2 for their compute, for any period, every figure traced to the meter.

  • Auditors

    Assurance providers who have to test a figure, not take it on trust.

    Gets: every figure traceable to its file, and the file itself to check.

The pilot

Become adesign partner.

We’re taking a small number of operators and reporters through a paid pilot. Priced in conversation, invoiced manually.

Your data
Processed locally under a signed pilot agreement — never uploaded to a hosted server until the pilot gate passes.
First report
On sample data, in about 20 minutes — on the first call.
Same engine
The calculation that runs in production, with its method and version on every figure.

Questions

What buyers ask first.

During a pilot, your files are processed locally under a signed agreement and are not uploaded to a hosted server. For ongoing use, hosting location is agreed before any data moves, and in-country hosting can be requested.

Every report is labelled self-reported, method documented, until an independent reviewer signs it — named and dated. We never imply a review that hasn’t happened.

From a published dataset, never from memory, with publisher and year shown beside every figure. The sample report’s factors are marked illustrative until a verified source is confirmed.

Personal data is handled under Nigeria’s Data Protection Act 2023. Application logs record actions and identifiers only — never file contents or credentials.